Interferometer Components  

The components required to build an interferometer vary significantly, depending on the dimensions of the sample and accuracy and performance needed. Interferometer components are offered as basic standard to reduce the time needed to assemble your desired interferometer system.

These components share the following common specifications:

  • Optical axis height: 170 mm
  • Efficient aperture: φ25 mm
  • Stabilized fixation by a φ20 rod and collet stand

Standard components have standard dimensions (including mounting screw diameters) for easy modification or addition, depending on the specific application. Indicate your intended purpose and budget constraints, and Sigma Koki will propose an ideal system for your needs.

 
 

Laser component IFC-L

A proven component equipped with a He-Ne laser and fine-tuning mechanism.

  • Wavelength: 632.8 nm
  • Output: 1 mW
  • Linearly polarized light

Also available are compact semiconductor laser components with lower optical axis. Optical axes change. Please contact us for more information.

Product name Part Number Price (JPYen) Code No.
HeNe Laser 05-LHP-111 98,000 1414001004
Power Supplies for HeNe Laser 05-LPL-911-065 74,000 1414001031
HeNe Laser Holdes LAH-2 25,000 1114003004
Post RO-20-80 (1,700) 1113001025
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

Spatial filter component IFC-SF

Component for converting light with noise into light with coherent wave fronts.

Collects light with an objective lens and removes noise elements with a pinhole. May be used as a beam expander in combination with the collimator lens component.

 

Product name Part Number Price (JPYen) Code No.
Spaitial Filter SFB-16 130,000 1114008001
Post RO-20-100 1,700 1113001026
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

Collimator lens component IFC-CL

A component for converting a laser beam into parallel light, together with spatial filter component.

Employs a spherical achromatic lens for improved wave fronts.

The three-axis lens holder allows easy fine-tuning of the optical axis (focus) direction.

Allows accurate collimation when combined with a collimation checker component (A15).

Product name Part Number Price (JPYen) Code No.
Spherical Achromatical Doublet DLB-50-100PM 18,000 3113615230
Three-axis Optics Holder ALH-50-3RO 47,000 1111030008
Post RO-20-100 (1,700) 1113001026
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

Mirror component IFC-M

A component for tilting optical path.

Employs a mirror with a profile regularity of λ/20 to suppress degradation of reflection wave fronts.

With easily switched coarse/fine control and minimal shifting of the optical axis, the gimbal mirror holder enables easy, accurate adjustment.

 

Product name Part Number Price (JPYen) Code No.
Aluminium Mirror TFA-50C08-20 30,000 3110000153
Ginbal Mirror Holders MHAN-50M 28,000 1111001005
Post RO-20-80 (1,700) 1113001025
Collet Post Holders CS-20A 8,800 1113004003
X axis Aluminum Crossed Roller w/Magnet Base TAG-601S 37,000 1115020001

Back to Top

Beam splitter component IFC-BS

A component for dividing and combining laser light.

With easily switched coarse/fine control and minimal shifting of the optical axis, the gimbal mirror holder enables easy, accurate adjustment. The XY-axis stage is joined to a magnetic base for easier adjustment, particularly for beam combining applications that require precise positioning.

 

Product name Part Number Price (JPYen) Code No.
Chromium plate half mirror PSCH-50C05-10-550 23,000 3110916151
Gimbal Beamsplitter Holders BHAN-50M 35,000 1111006002
Collet Post Holders CS-20A 8,800 1113004003
XY axis Aluminum Crossed Roller TAG-602S 64,000 1115020002

Back to Top

Concave mirror component IFC-CCM

Schlieren device incorporate a pair of concave mirror components.

The XY-axis stage joined to a magnetic base allows easier adjustment of reflective Schlieren devices, which demand simultaneous adjustment of focus and optical axis shiftings.

 

Product name Part Number Price (JPYen) Code No.
Aluminium Concave Mirror TCA-50C08-500 16,500 3110201518
Ginbal Mirror Holder MHAN-50M 28,000 1111001005
Collet Post Holders CS-20A 8,800 1113004003
XY axis Aluminum Crossed Roller TAG-602S 64,000 1115020002

Back to Top

Screen component IFC-SC

A screen for projecting interference fringes.

Product name Part Number Price (JPYen) Code No.
Flare Plates BBP-200 3,000 1114059001
SquareOptics Holders KMH-80 7,000 1111058002
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

CCD holder component IFC-CCDH

A component for displaying interference fringe on a monitor and for obtaining and sending data to a PC. A commercially available CCD camera is secured using a tripod-mounting screw (1/4").

Magnifies smaller beam interference fringes on a monitor for easier viewing; records changes in the interference fringe.

Product name Part Number Price (JPYen) Code No.
Camera Holders CMH-1 6,500 1114011001
Post (custom) RO-20-60(1/4") 2,800  
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005
CCD Option    
Monitor Option    

Back to Top

Collimation checker component IFC-SPV

A wedge plate-type sharing interferometer for easier evaluation of beam parallelism (divergence and convergence) during optical adjustment.

Compatible beam diameters are φ7 to φ25 mm.

A collimation checker component combined with a CCD camera is also available to enable evaluation of narrower beams. Please contact us for more information.

 

Product name Part Number Price (JPYen) Code No.
Beam Collimation Checker SPV-25 95,000 4101000008
Holder part SPV-25H 14,000 4101000010
Post RO-20-100 1,700 1113001026
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

Target component IFC-TG

Used as a reference to adjust the height and direction of the light path during optical adjustment.

The rear surface is a spring clip-type holder that can also be used as knife-edge holder for Schlieren devices.

Product name Part Number Price (JPYen) Code No.
Test Target Holders TGH-30 12,000 1114015001
Post RO-20-120 (1,700) 1113001028
Collet Post Holders CS-20A 8,800 1113004003
Magnetic Baces MB-L65C-M4 12,000 1113014005

Back to Top

Vibration Isolation Systems

 

Easy-setup darkroom

Attenuates the vibration from floor by air spring.

 

Allows easy setup of a darkroom to enable photographic development shielded from light sources.

 


SIGMA KOKI CO.,LTD.
Tokyo Head office
5F, SIGMA KOKI Tokyo Head office 1-19-9, Midori, Sumida-ku, Tokyo, 130-0021, JAPAN
TEL.+81-3-5638-8228 FAX.+81-3-5638-6550 international@sigma-koki.com
Osaka Branch
4-9-28 Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN
TEL.+81-6-6307-4835 FAX.+81-6-6307-4834
Kyushu Sales Office
3-17 Hie-machi, Hakata-ku, Fukuoka 812-0014, JAPAN
TEL. +81-92-481-4300 FAX. +81-92-481-4310